J Cardiothorac Surg ; 18(1): 137, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-37041623

RESUMEN

BACKGROUND: Unfractionated heparin is used worldwide as a standard anticoagulation therapy for extracorporeal membrane oxygenation (ECMO) machines. However, its use brings about significant bleeding and thrombotic complications for critically ill patients. This case report shows that low molecular weight heparin together with ECMO-produced primary haemostasis pathology can be used as an alternative way of ECMO anticoagulation. CASE PRESENTATION: This paper presents the case of a patient with respiratory failure who subsequently suffered from cardiac failure and spent 94 days on combined V-V and V-A ECMO devices (two ECMO devices running simultaneously on one patient) with intravenous enoxaparin used instead of unfractionated heparin anticoagulation. No life-threatening bleeding/thrombotic events happened during this period, nor did any technical problems with ECMO occur. CONCLUSIONS: In this case report, continuous intravenous low molecular weight heparin anticoagulation was used as a safe alternative to ECMO anticoagulation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trombosis , Humanos , Enoxaparina , Heparina/efectos adversos , Anticoagulantes/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Hemorragia/etiología , Heparina de Bajo-Peso-Molecular , Trombosis/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...